Dimensions and Connections:
Technical Specifications:
Part number |
NU75F30TR1MD |
Sensing range sd |
230 ~ 4000 mm |
Resolution |
1 mm |
Adjustment |
Yes |
Sonic frequency |
75 KHz |
Response time |
30 ms |
Voltage supply range +Vs |
10~30 VDC |
Current consumption max. |
35 mA |
Output signal |
4~20ma |
Adjustment |
Yes |
LED |
yellow |
solid yellow: object in the evaluation range |
|
|
yellow flashing: program function, object detected |
LED |
red |
solid red: Error |
|
|
red flashing: program function, object not detected |
Type |
|
Cylindrical |
Housing material |
nickel-plated /ABS |
Width / diameter |
30 mm |
Height / length |
90 mm |
Connection types |
Connector M12 |
Operating temperature |
-25~ +70 °C |
Storage temperature |
-40~+80°C |
Protection class |
IP 67 |
Programmed Analogue Output Function:A1: unusable area
A2: nominal sensing range
Mode of operation: rising ramp
- Adjusting The Evaluation Limits
The ultrasonic sensor features an analogue output with two teachable evaluation limits. These are set by applying the supply voltage -U or +U to the TEACH-IN input. The supply voltage must be applied to the TEACH-IN input for at least 1s. LEDs indicate whether the sensor has recognized the target during the TEACH-IN procedure. The lower evaluation limit A1 is taught with -U, A2 with +U.
TEACH-IN rising ramp (A2 > A1)
- Position object at lower evaluation limit
- TEACH-IN lower limit A1 with - U
- Position object at upper evaluation limit
- TEACH-IN upper limit A2 with + U
TEACH-IN falling ramp (A1 > A2): - Position object at lower evaluation limit - TEACH-IN lower limit A2 with + U
- Position object at upper evaluation limit - TEACH-IN upper limit A1 with - U
6. LED Displays
Displays in dependence on operating mode |
Red LED |
Yellow LED |
|
|
|
Teach-In evaluation limit |
|
|
Object detected |
Off |
Flash |
No object detected |
Flash |
Off |
Object uncertain (Teach-In invalid) |
On |
Off |
Normal mode (evaluation range) |
Off |
On |
Fault |
On |
Previous state |
Notes1: Precision instrument, please don't scratched the surface.
2: Do not use in strong acid and strong alkaline conditions.
3: Shall not be opened.
4: Cannot be used in the vacuum area or explosion-proof areas.
The interpretation is owned by us. If you have any questions, please feel free to contact us.